Industrial Gas Detector E2618 series

E2618 Features

  • Industrial enclosure with IP65 protection

  • Attached or remote sensor options

  • Two analog outputs settable to 4-20 mA or 0-10 V

  • RS485 Modbus RTU digital interface

  • Power supply 12...36 VDC (default), 24 VAC as option

Detects the following gases:

  • Ammonia NH3

  • Carbon Monoxide CO

  • Carbon Dioxide CO2

  • Chlorine Gas CL2

  • Combustible Gas LEL

  • Ethylene C2H4

  • Ethylene Oxide C2H4O

  • Hydrogen Sulfide H2S

  • Methane CH4

  • Nitric Oxide NO

  • Nitric Dioxide NO2

  • Oxygen O2

  • Ozone O3

  • Refrigerants HFC

  • Solvent Vapor VOC

  • Sulfur Dioxide SO2


AmmoniaAmmonia Detector

E2618-NH3-E - Ammonia Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3

  • Resolution 1 ppm NH3

  • 2x 4-20mA or 0-10V, RS485



E2618-NH3-P - Ammonia Detector

  • Stable long-life pellistor gas sensor

  • Range 0...15% vol. (0…100% LEL)

  • Resolution 0.1% vol. or 1% LEL

  • Wall mount or duct mount version

  • Attached or remote sensor

  • 2x 4-20mA or 0-10V, RS485


Acetylene

Butane

HexaneHydrogen

Octane

PropaneAmmonia Detector

E2618-LEL - Combustible Gas Transmitter

  • Stable long-life metal-oxide / pellistor gas sensor

  • Range 0...100% LEL

  • Resolution 0,1 / 1 % LEL

  • Wall mount or duct mount version

  • Attached or remote sensor

  • 2x 4-20mA or 0-10V, RS485




Carbon DioxideAmmonia Detector

E2618-CO2 - Carbon Dioxide Transmitter

  • Stable long-life photoacoustic or optical NDIR sensor

  • Range 0...10 000 ppm / 40 000 ppm / 5 %vol CO2

  • Resolution 1 ppm / 10 ppm / 0.01 %vol CO2

  • 2 × 4-20 mA or 0-10 V, RS485


Carbon Monoxide



Ammonia Detector

E2618-CO - Carbon Monoxide Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...300 or 0...1000 ppm CO

  • Resolution 1 ppm CO

  • 2 × 4-20 mA or 0-10 V, RS485


ChlorineAmmonia Detector

E2618-CL2 - Chlorine Detector

  • Stable long-life electochemical sensor

  • Range 0...10 ppm Cl2

  • Resolution 0,1 ppm Cl2

  • 2 × 4-20 mA or 0-10 V, RS485


EthanolSolvent Vapors Transmitter

E2618-PID - Solvent Vapors Transmitter

  • Highly sensitive Photo Ionization Detector

  • Range 0...40 or 0...200 ppm isobutylene

  • Resolution 0,01 ppm or 1 ppm isobutylene

  • 2 × 4-20 mA or 0-10 V, RS485



E2618-VOC - Solvent Vapors Transmitter

  • Stable long-life metal-oxide sensor

  • Range 0...100% LEL or 0...1000 ppm

  • Resolution 0,1% LEL or 1 ppm

  • 2 × 4-20 mA or 0-10 V, RS485


EthyleneAmmonia Detector

E2618-C2H4 - Ethylene Detector

  • Humidity compensated electrochemical sensor

  • Range 0...10 / 0...200 / 0...1500 ppm C2H4

  • Resolution 0,1 / 1 / 1 ppm C2H4

  • 2 × 4-20 mA or 0-10 V, RS485


Ethylene OxideAmmonia Detector

E2618-ETO - Ethylene Oxide Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...20 or 0...100 ppm C2H4O

  • Resolution 0,1 ppm or 1 ppm C2H4O

  • 2 × 4-20 mA or 0-10 V, RS485


HalocarbonsAmmonia Detector

E2618-HFC - Refrigerant Transmitter

  • Stable long-life metal-oxide sensor

  • Ranges 0...1000 / 0...2500 ppm halocarbon gas

  • Resolution 1 ppm halocarbon gas

  • 2 × 4-20 mA or 0-10 V, RS485


Hydrogen SulfideAmmonia Detector

E2618-H2S - Hydrogen Sulfide Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...100 or 0...2000 ppm H2S

  • Resolution 1 ppm H2S

  • 2 × 4-20 mA or 0-10 V, RS485


MethaneAmmonia Detector

E2618-CH4 - Methane Transmitter

  • Stable long-life metal-oxide / pellistor sensor

  • Range 0...100% LEL CH4

  • Resolution 0,1 / 1 % LEL CH4

  • 2 × 4-20 mA or 0-10 V, RS485


Nitric OxideAmmonia Detector

E2618-NO - Nitric Oxide Transmitter

  • Stable long-life electrochemical sensor

  • Detection range 0...250 ppm NO

  • Resolution 1 ppm NO

  • 2 × 4-20 mA or 0-10 V, RS485


Nitrogen DioxideAmmonia Detector

E2618-NO2 - Nitrogen Dioxide Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...20 or 0...200 ppm NO2

  • Resolution 0,1 ppm or 1 ppm NO2

  • 2 × 4-20 mA or 0-10 V, RS485


Oxygen



Ammonia Detector

E2618-O2 - Oxygen Transmitter

  • Electrochemical sensor

  • Range 0...25 %vol O2

  • Resolution 0,01 %vol O2

  • 2 × 4-20 mA or 0-10 V, RS485


OzoneAmmonia Detector

E2618-O3 - Ozone Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...5 ppm or 0...1 ppm O3

  • Resolution 0,01 ppm O3

  • 2 × 4-20 mA or 0-10 V, RS485


Sulfur DioxideAmmonia Detector

E2618-SO2 - Sulfur dioxide Transmitter

  • Stable long-life electrochemical sensor

  • Range 0...50 or 0...2000 ppm SO2

  • Resolution 0,1 ppm or 1 ppm SO2

  • 2 × 4-20 mA or 0-10 V, RS485


Volatile Organic CompoundAmmonia Detector

E2618-PID - Solvent Vapors Transmitter

  • Highly sensitive Photo Ionization Detector

  • Range 0...40 or 0...200 ppm isobutylene

  • Resolution 0,01 ppm or 1 ppm isobutylene

  • 2 × 4-20 mA or 0-10 V, RS485



E2618-VOC - Solvent Vapors Transmitter

  • Stable long-life metal-oxide sensor

  • Range 0...100% LEL or 0...1000 ppm

  • Resolution 0,1% LEL or 1 ppm

  • 2 × 4-20 mA or 0-10 V, RS485