Dual Gas Detector E2660 series

E2660 Features

  • Simultaneous detection of two gases

  • Easy to install enclosure with IP65 protection

  • Two analog outputs settable to 4-20 mA or 0-10 V

  • RS485 Modbus RTU digital interface

  • Power supply 12...36 VDC (default), 24 VAC or 230 VAC as options

Detects the following gases:

  • Carbon Monoxide CO & 

    Carbon Dioxide CO2 Simultaneously

  • Carbon Monoxide CO & Nitric Oxide NO Simultaneously

  • Carbon Monoxide CO & Nitrogen Dioxide NO2 Simultaneously

  • Carbon Monoxide CO & Combustible Gases LEL Simultaneously



Acetylene

Butane

HexaneHydrogen

Octane

Propane

Carbon Monoxide-Carbon Dioxide Transmitter

E2660-CO-LEL - Combustible Gases Transmitter

  • Simultaneous CO and combustible gases monitoring

  • RS485 Modbus RTU digital interface

  • Two analog outputs 4-20 mA / 0-10 V

  • Easy-to-install IP65 protected enclosure

  • Attached or remote sensor

  • Two SPST relays option

  • Acoustic alarm option


Carbon DioxideCarbon Monoxide-Carbon Dioxide Transmitter

E2660-CO-CO2 - Carbon Monoxide-Carbon Dioxide Transmitter

  • Simultaneous CO and CO2 monitoring

  • RS485 Modbus RTU digital interface

  • Two analog outputs 4-20 mA / 0-10 V

  • Easy-to-install IP65 protected enclosure

  • Attached or remote sensor

  • Two SPST relays option

  • Acoustic alarm option


Carbon MonoxideCarbon Monoxide-Carbon Dioxide Transmitter

E2660-CO-CO2 - Carbon Monoxide-Carbon Dioxide Transmitter

  • Simultaneous CO and CO2 monitoring

  • RS485 Modbus RTU digital interface

  • Two analog outputs 4-20 mA / 0-10 V

  • Easy-to-install IP65 protected enclosure

  • Attached or remote sensor

  • Two SPST relays option

  • Acoustic alarm option



Carbon Monoxide-Carbon Dioxide Transmitter

E2660-CO-NO - Carbon Monoxide-Nitric Oxide Transmitter

  • Simultaneous CO and NO monitoring

  • RS485 Modbus RTU digital interface

  • Two analog outputs 4-20 mA / 0-10 V

  • Easy-to-install IP65 protected enclosure

  • Attached or remote sensor

  • Two SPST relays option

  • Acoustic alarm option



E2660-CO-NO2 - Carbon Monoxide-Nitrogen Dioxide Transmitter

  • Simultaneous CO and NO2 monitoring

  • RS485 Modbus RTU digital interface

  • Two analog outputs 4-20 mA / 0-10 V

  • Easy-to-install IP65 protected enclosure

  • Attached or remote sensor

  • Two SPST relays option

  • Acoustic alarm option



Nitric OxideCarbon Monoxide-Carbon Dioxide Transmitter

E2660-CO-NO - Carbon Monoxide-Nitric Oxide Transmitter

  • Simultaneous CO and NO monitoring

  • RS485 Modbus RTU digital interface

  • Two analog outputs 4-20 mA / 0-10 V

  • Easy-to-install IP65 protected enclosure

  • Attached or remote sensor

  • Two SPST relays option

  • Acoustic alarm option

SL Process Measurement Pte Ltd

50 Gambas Crescent,
#10-15 Proxima@Gambas,
Singapore 757022

Kuala Lumpur, Penang
Tel / Whatsapp: +6011 55524838
Email: sl@slmeasurement.my

© 2024-2025. All rights reserved.

Johor, Singapore
Tel / Whatsapp: +65 87422778
Email: sl@slmeasurement.com.sg

a red play button sitting on top of a tablea red play button sitting on top of a table
blue and white letter bblue and white letter b
iconicon
a blue button with a white envelope on ita blue button with a white envelope on it
iconicon
a blue button with a white envelope on ita blue button with a white envelope on it

Contact us for inquiries and professional support.

Contact Us